Recent content by Pgeee

  1. Pgeee

    Official Caterpillar3116/3126 Thread

    Wow, it looks really neat. I bet you have a helm cover for it , the old stuff looked a bit sunburnt . Thanks for digging up the photos. My original systems monitor is temperamental hence the interest. Seems there are nice and simple little red led options out there , as opposed to breaking...
  2. Pgeee

    Official Caterpillar3116/3126 Thread

    Nice. Am interested to see your lights and buzzers setup. Did you make your own panel or something ?
  3. Pgeee

    Marinco 220v 50 Cycle shore inlet. But why

    My 1996 400db had line 1 shore power converted to 240v for Australia before I bought it. I have figured out just about everything as to how it works, a sweet combination of the original 110v generator and 110v appliances , as well as 240v sockets and a hunk of an isolating transformer that can...
  4. Pgeee

    40 sedan bridge forum

    I posted this recently on a generator install in a different boat type. It might give you some ideas on a gantry. Post in thread '40 sedan bridge forum' https://clubsearay.com/index.php?threads/40-sedan-bridge-forum.53961/post-1452573
  5. Pgeee

    40 sedan bridge forum

    Will you need to take the boat on one engine anywhere, there’s something about jury rigging cooling on the drip less to stop overheating on the shaft not in use
  6. Pgeee

    90s System Monitor Wiring

    Hi, did you resolve this. My monitor stops working sometimes, I suspect voltage sensitivity , but I may have to remove it to have a look. Whether wiring on my 400 is similar I don’t know but I can photo it if you think it will help you
  7. Pgeee

    40 sedan bridge forum

    If it was behind the tv it’s not now, no remnant of it. Maybe it’s below the tv box floor. (I’m turning that tv box into a cupboard as per your solution with a flat screen swinging out on the door)
  8. Pgeee

    40 sedan bridge forum

    Guest cabin A/C. Anyone know the route the air takes from the unit under the master bed to the outlet in the guest cabin. I get nothing , I suspect the PO removed that ducting or impeded it when he put a steel tube in as part of an added crane on the foredeck . I just wanted to check if it’s...
  9. Pgeee

    40 sedan bridge forum

    I’ve seen a few posts on this over the years , some say loosen off the mounts and rotate the unit to get access, I suggest search this thread for Westerbeke Impellar
  10. Pgeee

    Official Caterpillar3116/3126 Thread

    I use none also, at least not any I can notice , and except the time I left the dip stick not properly seated back in engines get light use only
  11. Pgeee

    Lithium Iron Phosphate battery charging from engine alternators

    Out of interest when you say wired into generator output, do you mean you wired into an existing generator circuit Dc to dc setups apparently have a loss factor in terms of lost energy, but only purists care I think
  12. Pgeee

    Fuel Filter primer pump

    Did you resolve this. On my 400 the primer to starboard is close to the crankcase breather, on port it’s near the forward bulkhead above the fuel filter . I.e searay made sure they are accessible for both engines
  13. Pgeee

    Australia- CAT 3116 oil (no rotella here and brand names are different )

    thanks all, Shell Rimula is a thing. As multigrade is now acceptable and as I have a non aftercooler set of 3116s, I reckon multigrade is the way to go for me, with all its fan dangle claims about engine life extending etc. And suddenly the infamous Rotella I read so much about seems to be an...
  14. Pgeee

    40 sedan bridge forum

    Ah I see. Hopefully you don’t have screws because the fasteners broke :)
  15. Pgeee

    40 sedan bridge forum

    btw 2nd inline muffler I assume is fine for Gas but I read somewhere it's not recommended by Westerbeke for Diesel because of back pressure.
Back
Top