DC issue

Radek Kobliha

Member
Sep 4, 2021
40
Boat Info
Sedan Bridge 360, year 2007
Engines
8.1 V8
Hey guys, I need your help please. Any idea why is my DC system showing 0V for both battery bank - PORT and STBD? All of the batteries are brand new and all of the switches and brakers are ON. Actually I can turn ON bilge blower, nothing else. I don't know what I am doing wrong. Boat is Sedan Bridge 360, year 2007 and I am a new owner (boat was sitting for a couple months). Thank you so much!
 

Attachments

  • IMG_20210828_181153.jpg
    IMG_20210828_181153.jpg
    85.9 KB · Views: 112
  • IMG_20210828_181159.jpg
    IMG_20210828_181159.jpg
    87.1 KB · Views: 104
Are your battery charger switches on (main distribution panel)?

And are your main battery switches on?
 
Yes, battery charger is ON and charging, also battery switch is ON. If I am trying to turn ON port or stbd on the DP I can hear click from relay, but nothing happened. What is weird all of the bilge pumps and bilge blower are working (they are green on the DP), but nothing else from DC (no lights, no stereo). Maybe electronic addressable module or bad ground? Thank you.
 

Attachments

  • IMG_20210901_191403.jpg
    IMG_20210901_191403.jpg
    185.8 KB · Views: 94
  • IMG_20210901_194521.jpg
    IMG_20210901_194521.jpg
    221.4 KB · Views: 99
Bilge pumps are powered before the switch 24x7 power
So if they run likely batteries are ok

the red lever on each is a manual override
Turn them on Locked symbol
If you get power the realy or control issue
 
Do you have a NEMA box where the main relays are? Need a picture of your main switch panel where you turn on your batteries. In the main box where the DC relays are located there are fuses (mine are 7.5 amp slow blow ATC). If my main battery on off switches are not working that is where you go, probably blown fuses that control the relay.
 
So you system is completely different with EDS. I looked up your diagrams and you have 2 100 amp breakers that feed power to your EDS controller. You need to verify you have 12v on the controller side of those.
upload_2021-9-5_10-14-45.png

I can't tell exactly but I think your breakers are off that feed these, check and reset the yellow levers and let us know.

upload_2021-9-5_10-16-32.png
 
So you system is completely different with EDS. I looked up your diagrams and you have 2 100 amp breakers that feed power to your EDS controller. You need to verify you have 12v on the controller side of those.
View attachment 111669
I can't tell exactly but I think your breakers are off that feed these, check and reset the yellow levers and let us know.

View attachment 111670


I checked all of the fuses and they are looks good. I think the breakers are showing label (I) like ON and (O) like OFF, not sure, I will check that. I think one of those bigger battery switches (with red lever) is not correctly working, I am not able to turn it ON or OFF like the others. I have to check that with multimeter. Thank you.
 
I checked all of the fuses and they are looks good. I think the breakers are showing label (I) like ON and (O) like OFF, not sure, I will check that. I think one of those bigger battery switches (with red lever) is not correctly working, I am not able to turn it ON or OFF like the others. I have to check that with multimeter. Thank you.
Yep the key is to read 12 volts in and out of those 100 amp breakers.
 
OK, I checked every single breaker and switch again. I have 13.5V on the 100A breaker, but weird think is, also when the breaker is on off position. Same think with those bigger battery switches, always measuring 13.5V no matter what, on or off position. I think one of them is bad (first one on the picture). Also the electric modules looks bad..thank you guys for helping
 

Attachments

  • IMG_20210905_192338.jpg
    IMG_20210905_192338.jpg
    64.6 KB · Views: 110
  • IMG_20210905_191801.jpg
    IMG_20210905_191801.jpg
    46.7 KB · Views: 105
  • IMG_20210905_191741.jpg
    IMG_20210905_191741.jpg
    103.3 KB · Views: 111
  • IMG_20210905_191734.jpg
    IMG_20210905_191734.jpg
    84.9 KB · Views: 105
  • IMG_20210905_191727.jpg
    IMG_20210905_191727.jpg
    135 KB · Views: 109
  • IMG_20210905_192507.jpg
    IMG_20210905_192507.jpg
    104.9 KB · Views: 106
  • IMG_20210905_192520.jpg
    IMG_20210905_192520.jpg
    94.1 KB · Views: 109
  • IMG_20210905_192503.jpg
    IMG_20210905_192503.jpg
    79.3 KB · Views: 105
Yea, a couple of those modules don't look good. Did you suffer from a high water situation in the bildge?
 
I had termites everywhere, but there are finally gone after tenting. No water. I probably gonna start replacing one thing by other..thank you
 
What do you think, how can I test those 3 gang battery switches (the big ones)? I have voltage on the output cable, but not sure, if they are working..
 
What do you think, how can I test those 3 gang battery switches (the big ones)? I have voltage on the output cable, but not sure, if they are working..
You can test everything with a volt meter.
 
Looks like a module 366hmm sr is bad and makes issue with DP. Do you guys know about some to buy? Thank you.
 

Attachments

  • IMG_20210905_192520.jpg
    IMG_20210905_192520.jpg
    94.1 KB · Views: 83

Forum statistics

Threads
112,945
Messages
1,422,750
Members
60,928
Latest member
rkaleda