Wiring of shower sump/bilge pump on 300DA

Discussion in 'Electrical Stuff' started by BocaDon, Oct 7, 2007.

  1. BocaDon

    BocaDon New Member

    12
    Oct 10, 2006
    Boca Raton, FL
    I'm "electrically challenged" and hope someone can clear my confusion!

    The "shower sump/air conditioner" drain bilge pump needed to be replaced. I bought an identical unit from Jabsco. It calls for a 5 amp fuse and the pump draws 4 amps. That is exactly the same as the pump it is replacing. The pump connects to a 3 amp Klixon circuit breaker on the bilge pump circuit breaker panel.

    Shouldn't that circuit breaker be 5 amp? How can the pump get it's 4 amps through a 3 amp breaker without tripping it or am I totally clueless, which is the likely answer?

    Do I still need to install a 5 amp fuse inline even though there is a 3 amp breaker?

    Thanks in advance for any advice.
     
  2. boatdoc100

    boatdoc100 New Member

    101
    Apr 9, 2007
    If it is already fused over fusing wont hurt but is not entirely necessary.
    Brad
    Pflieger Marine Services.
     
  3. boatmailster

    boatmailster Well-Known Member

    May 13, 2007
    NY
    none to share
    none to share
    klixton breaker rated 3A for constant use probably has 5-6 tripping amperage (should say on back of breaker)
    breaker will run warm/hot but wont trip with about 4 A current draw
     