generator

  1. Millhouse

    Alpha One Gen 2 transom assembly interchangeability question

    I recently purchased a 1998 Searay 290 W/ twin 350 and Alpha One gen 2 drives. I’m sadly pulling port engine so I can get 4E Kohler generator pulled to have it overhauled. While sizing up this job I noticed the transom assembly looks pretty rough so I figured it was the perfect time to...
  2. Reno Davis

    Main DC Breaker Panel - 2007 310 Sundancer

    I just recently purchased my first Sea Ray. It's a 2007 Sea Ray and I'm not fully understanding what to do with the Main DC Breaker Panel breakers and battery switches based on what the previous owner said they did with them. All I got was "I've never used it but I think you can swap between...
  3. Chris Cro09

    2002 Sun Dancer 260 - Adding an inverter

    So I just bought a 2002 Sun Dancer 260 and didnt realize it doesnt have a generator. It has AC, but it can only be run on shore power. Instead of adding a crazy expensive gen, can I just add a 3000w 12v inverter if I want to run the AC for about an hour or so with the motor/boat running? I am...
  4. RJAY

    Kohler 5 ECD generator help please

    Hello guys I know this has been talked about a lot on this forum. I have reviewed all treads and have done what have helped others but with no luck. Boat is a 2006 340. Gen has 115 hrs on it. Generator is throwing a LOC and shutting down about 15 seconds after full RPM is reached. I...
  5. C

    Kohler Generator Service

    I had a new generator installed on my 2010 Sundancer 310 last spring. This year it has failed to turn over (starts but then dies). My marina (Bass River on Cape Cod) has no one to service it. I called Kohler, and the names they gave me have no one either. If someone has a generator service...
  6. Michael Clark

    Leaking Kohler Generator

    Anyone had any problems with an exhaust leak on a gasoline Kohler Genset 5e on a 2004 Searay 420? Mine is setting off cabin CO alarms after about 15 mins of runtime. The sensors are all new and I keep the cabin door shut at all times. Any advice or ideas are welcome. Thanks in Advance Mike
  7. Nenad

    GENERATOR ONAN 7KW SEA RAY 44/455

    Hello friends, Can you tell me how to change lower plinth and girders on ONAN. Can we change it without getting out all generator because its pretty complicated ( in boat are motors cummins 8,3 QSC). If somebody had done that I would be so thankfull for any information or picture. The lower...
  8. Marrrs

    1996 Kohler 6.5CZ23 Generator - 101 Hours $3,800

    Ok here is what I got. 1996 Kohler 6.5CZ23 Generator with 101 hours. $3,800 Specs: Model: 6.5CZ23 Phase: Single Volts: 120 RPM: 3600 KVA: 6.5 Amps: 54.2 Hertz: 60 Watts: 6500 AMB.: 25C It also comes with the Operation and Installations Manual Generator would start and run if you hold the...
  9. D

    Westerbeke Serial Numbers

    I have a small issue. I entrusted my Westerbeke 7.0BCG (daihatsu ED10) cylinder head to a machine shop and they lost it. Thats a whole different discussion... sigh... however i was able to get a new head, however i need the camshaft. I could order it from westerbeke however I cannot figure out...
  10. M

    House Batteries

    Hi Everyone, My boat (SR 36DB) was in a harbor with no shore power a while and some of my batteries got depleted to less than 12v. Starting the engines was not a problem. So I thought that when I drive the boat going home, I expected the batteries to get recharged by the alternators...
  11. SHEENA OWENS

    ISO vacuume flush system

    We have a 1989 Sea Ray 340. Looking for a flushing system. We have the toilet already. If anyone knows where i could purchase a new one at a good price or if someone has a used one that works please message me or email. Sheenanicole803@gmail.com Also looking to upgrade Generator Ac unit if...
  12. M

    What Generator came Standard with a 1999 340 Sundancer??

    Hello all, I am trying to find out what generator came standard with 1999 Sundancer 340. Twin 7.4L, v drive. Was there an option on different makes or was it the same genny in all? Any insight would be helpful. Mojo Risin
  13. C

    Kohler 5E not starting and surging

    Greetings. I'd really appreciate some advice on my Kohler 5E generator. My generator was spitting fuel out the air intake when running, it was also surging. Clearly spitting fuel into the engine bay is a major safety hazard. I removed the carburetor and found that it was all clogged up and...
  14. Rochester 1

    Gen battery doesn't charge on shore Generator, battery,?

    New to me 97 sundancer 500 with 240v,120v,24v and 12v systems 7 battery's, 2 x12v =24v in series for Catapillar C12s, 2x12v in parallel for house, 1x12v for deisel westerbeke generator. 2 inverters, a 24v and a 12v. ....24v banks fine- batteries charge on shore and under way. 12v "house"charges...
  15. T

    5kw westerbeak gas for parts

    Recently removed my gas generator, electrical side is in perfect working order short block needs a complete rebuild. $1k takes the whole thing. From what I can gather electrical side alone runs over $1k to buy by itself.
  16. M

    Battery charging generator or mains

    We've had historically high water on Lake Lanier in Atlanta, and due to this, many marinas have had the power turned off for weeks. We took out our 2004 Sundancer 360 yesterday for a few hours to charge the batteries some (and it was a nice day!). The port motor fired right up, but the starboard...
  17. B

    Kohler generator parts

    Hi all After serving the brand since mid 1990's, we have resigned as a sales, service and warranty entity for Kohler Power Generation. We need to get the shelves and yard cleaned of the brand so that we can move ahead with the premium brands we serve. That said, we have in new parts inventory...
  18. J

    Generac QS 7.5 Shutting down after "hunting" or "surging"

    I know questions on this generator have been beat to death, but I have been pouring through the posts on the forum and I can't seem to find my specific issue previously posted. My QuickSilver Generator 7.5G starts fairly easily and runs smoothly. Handles the load of both AC units and with a...
  19. A

    Kohler 5EKD generator remote won’t turn on

    we have a 2016 330 Sundancer. Our generator has been working great. Low hours. Just used it a few weeks ago. Our remote in the cabin won’t turn on. Our generator is working fine. We can start it from the engine compartment. We had a fuse in position 1 that blew. We replaced it. We checked the...
  20. Christian

    Kohler 5E issue

    I have a Kohler 5e generator in my 340 sundancer. When i turn it on, it stay working for 5 min and then it turs off. Does anyone know the reason?
Back