no power transfer from genset to the boat ?

jfboucher

Member
Jun 4, 2008
59
Lac Champlain
Boat Info
390 Sundancer 2005
Engines
8.1s Mercs V-Drive
I have Kohler 5kw genset that runs smoothly. When I turn the main switch on to have the power transferred from the genset to the boat nothing happens. It worked just fine the last 9 yrs... I have a IOTA ITS-30R Automatic transfer switch hooked to it. Any switch or breaker somewhere I need to reset ?

Thanks

Sea Ray 320 Sundancer 2004 with V-drives - 6.2l
 
Check the black box on the generator. There is a switch to turn power on and off. I must have sat on mine working in the bildge (same boat) and tripped it off.


Sent from my iPhone using Tapatalk
 
Exactly right, there is a circuit breaker switch on the control module that was turned off. Quickly fixed. Thanks.
 