Air Conditionning Error code P5 ?

Discussion in 'General Maintenance/Repair Questions' started by jfboucher, Jun 22, 2008.

  1. jfboucher

    jfboucher Member

    59
    Jun 4, 2008
    Lac Champlain
    390 Sundancer 2005
    8.1s Mercs V-Drive
    I own a Sea Ray Sundancer 320 2004 and I cannot get any cold air from the a/c unit, it gives me a P5 code on the control after a few minutes of running. Any suggestions ? Heat and fan work just fine. Thanks.
     
  2. missnmountains

    missnmountains Active Member

    495
    Dec 12, 2007
    Florida
    2008 58 Sedan Bridge
    900 Man
    We just got that same code on our forward AC. I am having an AC guy look at it on Monday. The code is in your manual. The manual says high temp on the high pressure side due to lack of flow. We have a clear hose to the unit and there was no water in it. The AC guy thinks that it may be clogged up with growth.

    We got the following symptoms.

    The AC will turn on.
    It will run for a few minutes.
    The system shuts down and the P5 code flashes.

    I will let you know next week, but my guess is you are having the same lack of flow issue. My other thought was that a pump may be bad, but all of the other three AC units work fine.
     
  3. Robski97

    Robski97 Well-Known Member

    Jan 15, 2007
    North Bellmore, NY
    44DA
    Cummins QSC 8.3's
    JF,
    Are u sure its P5 and not PS..... can u hear the compressor running ... try and run... start anyting ? U said heat mode works.. in heat mode is water being discharged over board ? Alot questions.... the More u post the more we can help

    Rob

    Ps: just saw miss mountains post. Check the pump. Make sure ur not air bound...
     
    Last edited: Jun 22, 2008
  4. vanburen

    vanburen New Member

    324
    Feb 18, 2008
    Annapolis / Alexandria
    420 DB
    Cummins 480 CE
    Assume your air filter screen is all clear and clean?
     
  5. missnmountains

    missnmountains Active Member

    495
    Dec 12, 2007
    Florida
    2008 58 Sedan Bridge
    900 Man
    Robski, Is there a difference between P5 and PS? They look the same on the LED screen. I could only find the one in the manual. I am not trying to hyjack this thread, but we are getting that code also. I hope to know on monday.
     
    Luna Sea likes this.
  6. barryg

    barryg Member

    966
    Jun 24, 2007
    Fort Lauderdale
    2005 320 Sundancer, Garmin 5208
    Twin V-Drives 350 Mags
    Just had this happen to me a few nights ago in Bimini..Had the underwater swim platform lights on and must have sucked a small fish or something in the intake. Had the PS code, and the air would go on for a few and then the compressor would shut down and the error message would appear. No water was discharging so I knew the A/C was not getting the water it needed to cool. Opened and closed the seacock a bunch of times, opened and cleaned out the strainer, opened the seacock while the top of the strainer was open to make sure water flowed thru, then closed up and the A/C worked fine after that.

    So, check the strainer basket, open and close the seacock valve 3 or 4 times, make sure water is flowing thru with the seacock open (just for a moment), and you should be good to go. If not, after you've done all that, get the boat moving and see if that doesn't clear out what was stuck, and again if not, you might have blow out the line. Good luck
     
    Almightys likes this.
  7. Mystic Dreamer

    Mystic Dreamer Active Member

    392
    Oct 10, 2006
    St. Petersburg, FL
    2006 44DA
    Cummins QSC-500
    This must be the day to have AC issues- I too have a "HI PS" code on my Cruisair SMX salon AC. I do not have cooling water flow when the salon AC is cooling (but I do when the forward AC is cooling), so I am pretty sure it is a trigger in the relay box. This board has other threads that cover my issue, you may want to search under "trigger" to see if it helps you.

    Brian
     
  8. Mr Salt

    Mr Salt New Member

    632
    Jun 14, 2008
    Cape May, NJ
    Raymarine/Raytheon electronics, Sat TV, Yacht Controller
    2003 Caterpillar C-12s Twin Disc Transmissions
    I have had the HI PS code when the strainer sucks up mud and there is no water flowing through the heat exchanger. Mystic Dreamer are both of the air conditioners served by the same strainer/ water intake? If they are the problem is likely something else. If they are not served by the same strainer make sure the strainer is clean. Drive the boat to get any mud out of the under water scoop.

    Mr. Salt
    2001 540 CPMY
    C-12 Cats
     
  9. Robski97

    Robski97 Well-Known Member

    Jan 15, 2007
    North Bellmore, NY
    44DA
    Cummins QSC 8.3's
    Miss mountains . Its probably PS. Check to see if ur getting water out fwd tru hull for that a/c, They use one pump for all 3 a/c units. The MFING splitter is not at the pump . Its burried in some horrific place that on my 44 I can reach. I send the midget monkey down to blow out my lines 2x season. Why in gods name they can't put these things where there supposed too!!!!!!! ( with in normal reach) anyway... if ur getting water tru 2 of ur 3 a/c tru hulls u havea blockage. if no water from any tru hulls then it could be the triggers everyone talks about or something else. So post if theres water flow from all 3 tru hulls when u have the issue ... or only two or none ....

    Rob
     
  10. boatmailster

    boatmailster Well-Known Member

    May 13, 2007
    NY
    none to share
    none to share
    Before you pay somone for repair: check if your water pump starts, if does - prime the pump and should work like it used to.
     
  11. missnmountains

    missnmountains Active Member

    495
    Dec 12, 2007
    Florida
    2008 58 Sedan Bridge
    900 Man
    I guess I am Hyjacking. Sorry. The other three AC's are working fine. I cleaned the strainers (2). Nothing. The pump runs fines. I agree Robski. I think there is blockage. I turned on the forward AC and the relay pump. No water is discharging. When I turn on any other AC, water discharges. I too tried to trace the lines. They are buried. However, I did not find a splitter.

    Because the other three AC's are working, we suspect blockage.
     
  12. jfboucher

    jfboucher Member

    59
    Jun 4, 2008
    Lac Champlain
    390 Sundancer 2005
    8.1s Mercs V-Drive
    Finally found the problem. After checking the strainer, the seacock and the waterline for problems, turned out that the idiot who did the maintenance on the unit had hooked up the water lines backwards... All is fine right now... Thanks for help and suggestions.
     
  13. Robski97

    Robski97 Well-Known Member

    Jan 15, 2007
    North Bellmore, NY
    44DA
    Cummins QSC 8.3's
    That my friend was never even a thought .... howd u catch it ?


    Rob
     
  14. jfboucher

    jfboucher Member

    59
    Jun 4, 2008
    Lac Champlain
    390 Sundancer 2005
    8.1s Mercs V-Drive
    Once I had both hoses in my hands and was going to replug everything, it occurred to me that I could easily plug them back backwards myself... so why wouldn't that be the solution ? Could have saved myself the pain from going down under and cleaning everything for nothing... pretty cramped down there...
     
  15. Robski97

    Robski97 Well-Known Member

    Jan 15, 2007
    North Bellmore, NY
    44DA
    Cummins QSC 8.3's
    that would not be on the check list... GOOD CATCH...REALLY
     
  16. roadkingh1

    roadkingh1 Member

    278
    May 4, 2008
    Covington, La
    97' 370DA
    Twin 7.4l MPI v drive
    I have a forward cruisair ac unit doing the samething. It comes up with Hi PS. I thought at first it was an error code of Hi P5. The funny thing about the ac, it only errors out when I set the ac for 79 degrees or above. I have it set for 75 degrees and it has been running for a week. When I set it for 79 degrees it errors out within a matter of seconds. Did not mean to intrude, but I was hoping someone would tell me that I am not crazy.
     
  17. Four Suns

    Four Suns Not a pot stirrer TECHNICAL Contributor

    Oct 4, 2006
    Williamsburg, VA
    2003 480 DB
    QSM-11 Diesels
    Yet another dude who says "I have a problem..." and doesn't let anyone know what kind of boat he/she/it has. One would think after reading this board one would know not to post a question without that info... sell your boat.

    I say you have grass clippings in your outside heat exchanger. You do have a Trane don't you?
     
  18. Turtlesboat

    Turtlesboat Minister of Media TECHNICAL Contributor

    Feb 4, 2007
    New York City
    1996 450DA, TNT, Caribe dink w/15hp OB.
    3126 427HP TD transmissions
    I guess Gary hasn't seen the new pic....
     
  19. roadkingh1

    roadkingh1 Member

    278
    May 4, 2008
    Covington, La
    97' 370DA
    Twin 7.4l MPI v drive
    Gary, are you an Engineer or an electronic tech. I am talking about air conditioners. Why do you need to know what type of boat I have?
     
  20. First Born

    First Born New Member PLATINUM Sponsor

    Oct 3, 2006
    Charlotte, N.C.
    2006 185 Sport
    4.3 L 190 HP
    Why do you refuse to tell what type of boat you have? :huh:
     